Description
Nominal Current Range | 30 mA to 30 A DC 30 mA to 20 A AC rms |
Continuous AC Current Range | 5 mA to 30 A DC 30 mA to 20 A AC rms |
Highest Current | 30 A AC Peak |
Lowest Measurable Current | 50 mA |
Basic Accuracy (48-65 Hz)* | ?1% of reading ?2 mA |
Usable Frequency | DC to 100 kHz (-0.5 dB) |
Max Working Voltage | 300 V AC rms or DC |
Max Conductor Diameter | 19 mm diameter |
Output Level(s) | 100 mV/A |
Zero Error Adjustment | Manual Adjust via Thumbwheel |
Output Cable (m) | 2 m |
Power Supply | 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator |
Shrouded Banana Plugs | |
BNC Connector | ? |
BNC to Bannana Adapter | ? |
Safety | BS EN 61010-1: 2001 BS EN 61010-2-032: 2002 BS EN 61010-031: 2002 300 Vrms, Category III, Pollution Degree 2* EMC standards EN 61326: 1998 +A1, A2, and A3 |
* Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.